Unitrane fan coil and force flo cabinet heaters units are single room units with load capabilities of 200 to 1200 cfm.
Trane fan coil units horizontal concealed.
Hfcd series 50 hz.
Trane paid particular attention on the sound level during the development of the unit.
Size nominal airfl ow 02 200 cfm 03 300 cfm 04 400 cfm 05 500 cfm 06 600 cfm 08 800 cfm 10 1000 cfm 12 1200 cfm 14 1400 cfm digit 7.
Force flo units feature 2 pipe hydronic coils electric heat.
Each digit in the model number has a corresponding code that identifies specific unit options.
Not all options are available on all cabinet styles.
Contact us to find out more.
Digits 1 2 unit type fc fan coil digit 3 model a vertical concealed b.
Fan coil units are available as 2 pipe with or without electric heat one hydronic circuit or 4 pipe two hydronic circuits.
Inverted unit models allow heating to circulate from the bottom of the unit.
Indoor air quality iaq features easy installation and maintenance high quality and.
H horizontal digit 2.
Units are horizon tal concealed and are available with an exposed fan plenum or ceiling access panel.
Trane unitrane fan coil units meets the standards of today s market and.
Page 1 unitrane fan coil air terminal devices horizontal vertical and low vertical sizes 02 12 basic series fan coil sizes 04 08 unt prc001 en december 2000.
Basic series fan coil unit.
All control end devices and moving components fans and motors are computer tested after.
Quality coils and piping packages are leak tested before mounting on the unit.
Supply fan hydronic.
C concealed digit 4.
Coil piping connections are also leak tested after mounting on the unit.
Thanks to an ec motor and the zn control s continuous and variable speed control the fed fan coil can achieve exceptionally low sound levels without perceivable.
Ship loose accessories include a remote mounted fan speed switch ball valves and control valves.
Page 2 it isn t just a fan and a coil the trane company has redesigned the traditional fan coil to lead the industry in.
See figure 1 for unit components.
The basic features of our standard unitrane fan coil.
General information drain pan figure 1.
Thus reducing by several db the overall sound level of the unit compared to the previous range.
Chilled water fan coil units for district cooling plant.
F design sequence digit 5 6.
Unitrane harmony fan coil units are available as both cabinet and concealed versions with a wide array of options.
In addition renovation has overtaken new construction in the fan coil units market demanding a design that caters to renovation issues.
Unitrane fan coil model number.